SMARTDC CONTROLLER TROUBLESHOOTING
Table 11. SmartDC Controller - Troubleshooting
Table 11. SmartDC Controller - Troubleshooting
Ref.
No�
Display
Description
Possible Causes
Solutions
Condition
Alert, Error or Fault
10
ALERT 2
DRIFT CLOSED
Gate drifted closed.
The gate has been forced
off its open limit and is
being prevented from re-
opening. Must be enabled
in User Menu.
Will self-clear after an open or
close input.
11
ALERT 3
EXCESS DRIFT
Gate drift in transit.
Advisory only
.
Alert appears if gate drifts
three times in a five minute
period.
Check track to make sure it is
level.
12
ALERT 4
MOTOR
OVERLOAD
Thermal overload
alert. When the alert is
triggered, the gate can
only “fully open” until
the alert is cleared.
Motor drive heat sink
exceeds 195⁰F (90.56⁰C).
The alert will temporarily
disable the operator, but
will automatically reset
itself when it cools down.
May also occur if the
heatsink temperature is
70°F (21.11⁰C) higher than
ambient temperature.
Check gate hardware,
weight/length of gate. Alert
automatically clears when
the temperature drops below
threshold.
13
ALERT 5
BOTH LIM
ACTIVE
Both limit switches are
on at the same time.
1.
Stuck limit switch.
2.
Short in wiring.
3.
Debris in limit plate
area.
1. Check limit switches and
replace as required.
2.
Repair any wiring issues.
3.
Remove debris from limit
plate area.
14
ALERT 6
LIM NOT
RELEASED
The limit did not release
when the operator was
commanded to move.
1.
Quick disconnect bolt
missing.
2.
Broken drive belt.
3. Hardware holding the
arm.
4. Stuck Limit Switch.
5.
Broken Limit Plate.
6.
Debris in limit plate
area.
1.
Ensure quick disconnect
bolt is in place and tight.
2. Check and replace drive
belt.
3.
Release any holds on the
arm
.
4.
Check limit switches and
replace as required.
5.
Check Limit Plate and
replace as required.
6.
Remove debris from limit
area.
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......