SMARTDC CONTROLLER TROUBLESHOOTING
Table 11. SmartDC Controller - Troubleshooting
Table 11. SmartDC Controller - Troubleshooting
Ref.
No�
Display
Description
Possible Causes
Solutions
Condition
Alert, Error or Fault
19
ALERT 11
DETECTOR
FAULT
The SmartDC Controller
has detected a problem
within a HY5B vehicle
detector.
Caused by a fault within
the HY5B. This message
will also indicate which
detector the alert applies
to: Exit Loop (ELD), Inside
Obstruction Loop (IOLD),
Outside Obstruction Loop
(OOLD), or Center Loop
(CLD) - (User Relay 22)
.
Remove and re-install the
HY5B and press RESET. Replace
the HY5B, if necessary.
20
ALERT 12
ON TOO LONG
The SmartDC Controller
has an active loop input
(HY5B or box detector
output) for more than 5
minutes.
Caused when the SmartDC
Controller sees an active
loop for more than 5
minutes. The “active” loop
can be actual or false. This
message will also indicate
which detector the alert
applies to: Exit Loop (ELD),
Inside Obstruction Loop
(IOLD), Outside Obstruction
Loop (OOLD), or Center
Loop (CLD) - (User Relay
22)
.
Check traffic patterns at the
site. The loop and lead-in
wires should be checked for
problems or replaced.
21
ALERT 13
STIFF GATE
The SmartDC Controller
has detected a gate that,
over time, has taken
more power to move
than it used to.
Caused by degrading gate
hardware or debris in track.
This alert appears in the
history log. It does not have
any effect with regard to
opening or closing the gate.
Check and correct gate
hardware as required.
22
ALERT 14
STUCK GATE
The SmartDC Controller
has detected that it
cannot move the gate
at all.
Caused by broken gate
hardware or ice/snow
buildup.
Check and correct gate
hardware as required.
23
ALERT 15
NO PICKLE
Not used.
--
--
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......