SAFETY STANDARDS - INSTALLER'S RESPONSIBILITY
•
Connect radio and other remote access (non-resetting controls) to the RADIO OPTIONS terminals.
•
Open and close the gate to confirm that it was properly installed and to ensure reduced risk of
entrapment. Verify the clearance between the gate and adjacent structures per UL 325 Safety
Standards. Have a qualified technician test the gate monthly.
•
When you complete the installation, show the end user how to:
- Remove the operator covers and turn the power off and on.
- Turn the DC power switch off, which disengages the motor.
- Loosen the quick disconnect and manually push the gate(s) open & close.
•
Remember to re-tighten the quick disconnect before turning the DC power switch back on and
replacing the covers.
•
Test the red Stop Button located on the side of the control box.
Gate system instructions must be
given to the owner per UL 325 Safety
Standards.