SMARTDC CONTROLLER TROUBLESHOOTING
Table 11. SmartDC Controller - Troubleshooting
Table 11. SmartDC Controller - Troubleshooting
Ref.
No�
Display
Description
Possible Causes
Solutions
Condition
Alert, Error or Fault
45
ERROR 7
MENU
CHECKSUM
Software issue exists
that may require factory
reset.
Corrupt software or data.
Call Technical Support for
assistance.
46
ERROR 8
RPM SENSOR
Not used.
--
--
47
ERROR 9
BATTERY
DISCONNECT
The SmartDC Controller
detected there is no
battery connected.
The batteries are
disconnected, or a wiring
fault exists. FoldSmart
operators ship with a wire
disconnected to prevent
battery drain. Replaced by
Alert 29 in h5.57 software
version
.
1.
Ensure the red wire in the
upper left corner of the
electrical box is connected
to the switch.
2. Correct any issues with
battery wiring.
3. Check the 35-amp fuse on
the circuit board.
48
ERROR 10
SLOWDOWN
SWITCH
Not used with DC
operators.
--
--