EXTERNAL ENTRAPMENT PROTECTION SENSORS
External Entrapment Protection Sensors
FoldSmart is equipped with a Type A inherent entrapment sensor (IES). UL 325 Safety Standard compliance
requires installation of external entrapment protection sensors, the number of which, depends on the
entrapment hazards that exist at each particular installation.
To comply with UL 325, the following external sensors may be used:
•
Contact sensors, such as edge sensors
• Non
-
contact sensors, such as photoelectric eyes
The site designer or installer can choose either photoelectric eyes or edge sensors or use these devices
in combination. Whatever devices are used, protection in both the opening and closing directions of gate
travel must be provided.
The UL 325 Safety Standard for automatic swinging gates specifically requires that edge sensors or
photoelectric eyes or a combination of both devices be installed to protect against pedestrian entrapment
in BOTH directions of the gate travel and where an entrapment hazard exists.
PHOTOELECTRIC EYES:
One or more photoelectric eyes shall be located where the risk of entrapment or
obstruction exists, such as the perimeter reachable by a moving gate.
A photoelectric eye or contact
sensor is also required to protect
against possible entrapment if the
gate opens to a position less than
16 inches (40.6cm) from any object,
such as a post or wall.
EDGE SENSORS:
One or more edge sensors shall be located on the inner and outer leading edge of a swing
gate where the risk of entrapment or obstruction exists. If the bottom edge of the swing gate is situated
more than 6 inches (152 mm) above ground level at any point in its arc of travel, one or more contact
sensors must be located on the bottom edge, as well.
SENSOR SECURITY:
A hard -wired sensor shall be located and its wiring arranged so that communication
between the sensor and gate is not subjected to mechanical damage.
SENSOR FUNCTION and COMMUNICATION:
A sensor that transmits its signal to the gate system must
be located so its signal is not impeded by building structures or other obstructions. All sensors must be
installed so that they function as intended for the end-use conditions.
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......