FoldSmart™ Installation and Maintenance Manual
Revision 1 - MAY 2023
43
INSTALLATION ADJUSTMENTS
Manual Release Procedure
The FoldSmart gate has a manual release
procedure should the gate not be able to move
electronically.
1�
Before performing this procedure, ensure the
DC power switch is in the Off position. DO
NOT turn AC power Off.
2.
The 3-piece FoldSmart linkage arm has a
quick disconnect bolt connecting the two
gearbox side pieces together. When this
bolt is removed, it allows the top piece
to move separately from the bottom,
effectively allowing the gate panels to move
independently of the gearbox.
3.
The quick disconnect bolt can be removed
by utilizing the manufacturer-supplied Penta
key. The gate owner will be able to provide
the storage location of the Penta key. We
recommend keeping it in one of the FoldSmart
control cabinets for quick access in the event
of an emergency. The key can be used with
a 1/2-inch socket. This socket is not supplied
with the gate.
4.
Note that when the gate is fully closed, the
gearbox section of the linkage arm may
prevent the gate panels from moving to the
fully open position. In the event this occurs,
the drive belt may need to be disconnected to
allow the gearbox section of the linkage arm
to be moved out of the way.
5.
When re-installing the quick disconnect bolt,
position the gate such that the two sections
of the gearbox side of the drive linkage are in
line. Re-insert the bolt and thread clockwise
until tight. Do not overtighten the bolt.
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......