WIRING 208/230VAC POWER
Wiring 208/230VAC Power
All FoldSmart operators are shipped
from the factory as 115VAC units.
When connecting to 208/230VAC
power, the voltage selector switch on
the AC power board must be moved
to the 230V position or damage to
the operator will occur and void the
Limited Warranty.
For the 208/230VAC power connection:
•
Verify AC power supply wires and low voltage (12V & 24V accessory power wires) run through two
separate conduits as discussed in Wiring 115VAC Power.
•
Maximum gate system current draw is 1.5 amps on a dedicated 208/230VAC circuit (20A dedicated
circuit is recommended).
•
Make sure proper wiring is being used. Refer to the following table:
AC Power
14-gauge wire
12-gauge wire
10-gauge wire
One operator 208/230V
2095 ft (639 m)
3350 ft (1021 m)
5300 ft (1615 m)
Two operators 208/230V
1465 ft (446 m)
2350 ft (716 m)
3750 ft (1143 m)
Table 2. Wire Gauge versus Run for 208/230VAC
Table 2 assumes a dedicated circuit. Additional loads require that the wire size be increased or the distance
of the run be decreased.
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......