FoldSmart™ Installation and Maintenance Manual
Revision 1 - MAY 2023
81
INSTALLER MENU FUNCTIONS
Table 5. SmartDC Controller - Installer Menu Functions
Table 5. SmartDC Controller - Installer Menu Functions
Ref.
No�
Installer Menu
Setting Options
(
Bold
= Factory Settings)
Menu Tasks and Explanations
Associated
DC Controller
Connections
Display
30
OR 1 REVERSE
OUTSIDE OBS LOOP
0 = Pause closing only
1 = Enable reversing to
open
The default is for full reversal when the
Outside Obstruction Loop is triggered while
closing. A setting of 0 causes the gate to
only pause when triggered. Gate closure
continues as soon as the loop is clear again.
OUTSIDE OBS
LOOP
COM or
HY5B
31
IR 1 REVERSE
INSIDE OBS LOOP
0 = Pause closing only
1 = Enable reversing to
open
The default is for full reversal when the
Inside Obstruction Loop is triggered while
closing. A setting of 0 causes the gate to only
pause when triggered. Closure begins as
soon as the loop is clear again.
INSIDE OBS
LOOP
COM or
HY5B
32
HD 1 HOLD OPEN
CENTER LOOP HOLD
0 = Hold open only
1 = Hold close and hold
open
Configures the function of the Center Loop
(Shadow Loop) when triggered:
Setting 1 – prevents opening and closing of
the gate when the Center Loop is tripped if
the gate is on either (opened or closed) limit
switches.
Setting 0 – prevents closing when on the
open limit switch.
CENTER LOOP
COM
33
DL 1 STANDARD
DETECTOR LOGIC
1 = Standard
2 = Quick closed
3 = Forced Time out
4 = Full anti-tailgate
This selection determines whether the close
timer begins to count down after vehicles
have departed the detector loops or whether
the close timer will count down while the
loops are occupied. The gate can only close
when all loop detectors are clear.
The default setting causes the Close Timer
to start when all loops are clear. A setting of
2 causes the Close Timer to start when the
open limit is reached.
A setting of 3 forces the Close Timer to
0 when the OOLD and IOLD are tripped
simultaneously. A setting of 4 stops the
gate when OOLD and IOLD are tripped
simultaneously and closes from that point
when the loops clear.
HY5B
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......