INSTALLER MENU FUNCTIONS
Table 5. SmartDC Controller - Installer Menu Functions
Table 5. SmartDC Controller - Installer Menu Functions
Ref.
No�
Installer Menu
Setting Options
(
Bold
= Factory Settings)
Menu Tasks and Explanations
Associated
DC Controller
Connections
Display
38
LT 3 (75 SECS)
LOITERING ALERT
0 = 0 seconds delay
1 = 15 seconds
2 = 45 seconds
3 = 75 second delay
4 = 105 seconds
5 = 135 seconds
This function monitors activation of the
Outside Obstruction Loop when the gate is
closed and not running. When the adjustable
period of time is exceeded, User Relay
No. 13 triggers and reports loitering in the
diagnostics log.
Adjust the time delay before activating the
user relay. Maximum time setting is 135
seconds. See
Setting the User Relay Function
in the Installer Menu.
Note:
This menu appears only when a user
relay is set to Function No. 13.
User relays
39
SA 0 (OFF)
SDC ADDRESS
0 = No network
1 to 99 = Network
“drop” address
Sets the system address for network
communication:
0 = no network communication
1-99 sets individual polling addresses. Use
addresses 1-4 when connecting to HyNet.
RS-485
40
ELD 0 (RUN MODE)
EXIT LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY5A/HY5B/HY5B 2.0 Free
Exit detector. If an HY5B is used, additional
settings of 4-8 are available:
4 = Show Sensitivity
5 = Set Sensitivity
6 = Show Inductance
7 = Show Loop Health
8 = Set Presence
HY5A/HY5B/
HY5B 2.0
41
ILD 0 (RUN MODE)
IN OBS LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY5A/HY5B/HY5B 2.0 Inside
Obstruction Loop detector. If an HY5B is
used, additional settings of 4-8 are available:
4 = Show Sensitivity
5 = Set Sensitivity
6 = Show Inductance
7= Show Loop Health
8 = Set Presence
HY5A/HY5B/
HY5B 2.0
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......