VEHICLE DETECTOR CONFIGURATION AND QUICK CLOSE MODE SELECTION
Vehicle Detector Configuration and Quick Close Mode Selection
The Standard Quick Close modes are selectable in the Installer Menu. Refer to
Controller - Installer Menu Functions” on page 75
The two selectable modes are described as follows:
Mode 1 (Default)
An input from either the Free Exit, Outside Obstruction Loop, Inside Obstruction Loop or the Center Loop
will hold the gate open, reset the close timer, and block all close inputs.
Mode 2
Same function as Mode 1, except the close timer can count to zero even with the Free Exit, Outside
Obstruction Loop, Inside Obstruction Loop or the Center Loop detector inputs active. If the close timer
has counted to zero, the gate will close when all detector inputs are clear.