USER RELAYS - PROGRAMMING PROCEDURE
Table 8. User-Programmable User Relays - Function Options
No�
Name
Description
23
External Latching Gate
Lock output
Not functional in the FoldSmart operator.
24
Gate at Partial Open
Position
Not functional in the FoldSmart operator.
25
DC Power Alert
Active when on AC power or the battery voltage is above 21V. When
used with User Relay 2, this option can shed electrical loads to conserve
battery energy.
26
Free Exit Loop Detector
pulse
Outputs a 250ms pulse when the free exit vehicle detector is tripped.
27
Not Open (w/AC power)
Activated when gate is not on open limit and AC power is present.
Deactivated when AC power fails or the gate is on open limit.
28
Flasher (w/AC power)
Output identical to relay #19 and pulses relay 500 ms/sec when the
gate is not on open limit and AC power is present. Deactivated when
AC power fails or the gate is on open limit.
29
Arm Entry Ticket
Dispenser
Not functional in the FoldSmart operator
.
30
Arm Exit Ticket Dispenser
Not functional in the FoldSmart operator
.
31
Reset Ticket Dispenser
Pulse
Not functional in the FoldSmart operator
.
32
Backoff Pulse
Not functional in the FoldSmart operator
.
33
Transient In Pulse
Not functional in the FoldSmart operator
.
34
Transient Out Pulse
Not functional in the FoldSmart operator
.
35
Tenant In Pulse
Not functional in the FoldSmart operator
.
36
Tenant Out Pulse
Not functional in the FoldSmart operator
.
37
Special In Pulse
Not functional in the FoldSmart operator
.
38
Special Out Pulse
Not functional in the FoldSmart operator
.
39
Unknown In Pulse
Not functional in the FoldSmart operator
.
40
Unknown Out Pulse
Not functional in the FoldSmart operator
.
41
Test Open Pulse
Output pulses five seconds after close limit is activated. Typically used
for cycle testing.
42
Break-Away Switch output Activates when the arm break-away switch is tripped.
43
Warn Before
Combination of relays #5 and #16.
44
Partial Open Limit Pulse
Pulses for 250ms when the gate, commanded with Partial Open input,
reaches Partial Open Limit, or, the gate is past Partial Open Limit and
Partial Open input is activated. Note: This item is not functional in the
DC FoldSmart operator.
45
Outside Obstruction/
Arming Loop Detector
Activated when OOLD/OALD detector input tripped and gate closed.
Used for testing purposes.
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......