106
wallaceperimetersecurity.com
Phone: 866.300.1110
INSTALLING A MAGLOCK OR SOLENOID LOCK
Installing a MagLock or Solenoid Lock
To provide additional gate security, a maglock or a solenoid lock can be used and connected to the SmartDC
Controller. The SmartDC Controller releases the lock prior to initiating gate movement. Before installing
the lock, be sure to:
•
Determine the electrical power requirements of your lock (maglock or solenoid lock). Electronic
board and peripheral connections differ between high voltage and lower voltage gate systems.
•
Determine the current required. The 24VDC or 12VDC terminals supply up to 1 ampere. If the
peripherals attached to the terminals need more than 1 amp, a separate power supply is required.
Installing a Lock for 12VDC or 24VDC Systems
To install a lock for 12VDC or 24VDC systems,
take the following steps:
1�
Connect a wire between COM on USER
1 RELAY and a COM terminal on the
electronics board. See Figure 20.
2�
Connect the power lead from the lock to
the appropriate power spade (+24VDC or
+12VDC)
.
3. Connect the common wire from the lock
to NC on USER 1 RELAY.
Connect to NO on USER 1 RELAY if installing a
Solenoid lock.
4�
Set the User Relay function in the Installer
Menu to RL1 - 6. Refer to
User Relay Function in the Installer Menu”
�
Figure 20
.
Lock on 12VDC or 24VDC Systems
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......