WIRING AC POWER
Wiring AC Power
Turn off AC power at the source (circuit
breaker panel) before accessing
the wires in the FoldSmart junction
box. Follow facility Lock Out/Tag Out
procedures. Make sure both the DC
and AC power switches, on the side of
the FoldSmart control box
,
are in the
off position. See Figure 2.
Wiring of gate systems must conform
to the NEC standards and comply
with all local codes. If you plan to
connect to 208/230VAC power, read
the voltage selector switch WARNING.
See Figure 2. The voltage selector
switch on the AC Power board must be
moved to the 230V position or damage
to the operator will occur and void the
Limited Warranty.
Figure 2. Wiring AC Power
DO NOT connect the 115VAC service
outlet to 208/230VAC power supply
wires. To use the 115VAC service
outlet on a 208/230VAC installation,
the electrician needs to run an extra
neutral wire to the operator from the
power source and wire the service
outlet per code.