Installation
Protection of pipes, hoses and cables
Power cables and fuel hoses must be protected in locations where they are sus-
ceptible to mechanical damage due to sharp edges or heat.
Safety distances
Distance from surrounding walls.
Observe country-specific requirements.
There must be enough clear-
ance between the wall and
the device so that the space
can be kept clean and free of
dust, litter and other unwanted
objects. The openings for the
air intake, in the lower section
of the device’s casing, must be
unobstructed.
There must be no surfaces,
structures or objects that are
flammable or can obstruct the
heat, within 1 m above the
device’s upper surface.
Safety distances
Device over 1300 m above sea level
If the device is installed over 1300 m above sea level, a short circuit connector to
activate the mountain switch has to be added into a connector J14 of the device’s
circuit board. The connector is in the accessory bag.
Do not remove the jumper (or change its location) from the device’s circuit board.
Always use original Wallas accessories and parts with Wallas equip-
ment.
en
Short circuit connector
for mountain switch
26CC / 40CC
D80151
- 42 -
min 70 mm
min 100 mm (SE)(NO)
min 50 mm
min 1000 mm
490525C