Installation
protrudes from the wall ca. 10 mm, and cut the edge of the sheet metal into
10–20 mm strips (28), as shown in
picture 1
. Fold the strips carefully on to the
surface of the sheet metal cover.
17.
Seal the clearance between the sheet metal cover (17) and the flue-gas ex
-
haust head (15) with silicone paste and push the head into place in the wall.
Attach the head to the wall with screws (30, 4 items 4,5x25). The lid of the flue-
gas exhaust head (15) must be opened before installation - screw (31). Ensure
that the ends of the hoses (23 and 24) extend to the limiters (32 and 33).
18.
Finally, fasten the heater to the floor or the base housing (12).
Installation measurements
Additional insulation
Installation measurements
Measurements in Finland
Measurements in Sweden and Norway
Note the different measurements in Finland compared to Sweden and
Norway.
ø 320 mm insulation
en
26CC / 40CC
D80151
- 44 -
28
30
ø 50 mm
ø 120 mm
100 mm
255 mm
275 mm
26CC
40CC
155 mm
175 mm
26CC
40CC
100 mm
28
30
34
34
490525C