5
800 D S
490549
Flue gas connections
Flue gas lead-throughs
Flue gas lead-throughs
1066
and the closable model
2466
are suitable for this
device.
$OOÀXHJDVOHDGWKURXJKVDUHVWDLQOHVVVWHHO7KH¡PPOHDGWKURXJKV¿WWKH
ÀXHJDVSLSH
1028
.
*HQHUDOLQVWUXFWLRQVIRUÀXHJDVFRQQHFWLRQV
LOCATION
$LUPXVWDOZD\VÀRZIUHHO\SDVWWKHOHDGWKURXJK,QVWDOOWKHOHDGWKURXJKRQDÀDW
surface. Avoid corners or recessions where wind pressure can disturb the function-
ing of the device.
7KHPLQLPXPGLVWDQFHRIWKHOHDGWKURXJKIURPWKHIXHOWDQN¶V¿OOHUKROHLVPP
(16”).
The minimum distance of the side lead-through from the surface of the water is
500 mm (20”). Especially in sail boats it should be noted that the lead-through must
never be submerged.
It is recommended to place the lead-through in the side as far back as possible or
directly in the transom.
INSTALLATION
When preparing the installation cut-out for the lead-through, it is a good idea to use
the lead-through as a model for the cut-out; especially if the lead-through is circu-
lar. If necessary, seal the installation cut-out with silicone in addition to the lead-
through seal. Note! Do not use silicone on a wooden boat.
The side lead-through must always be equipped with a so-called goose neck sec-
tion.
The goose neck will effectively prevent splash water from getting to the device.
The highest point of the goose neck must always be above the surface of the wa-
ter.
The device will go out, if the exhaust gas lead through is submerged.
OTHER THINGS TO NOTE
Exhaust gas is hot. Always ensure that there is nothing that is susceptible to heat
damage within 200 mm (8”) of the effective area of the exhaust gases (e.g. ropes,
fenders or the side of another boat).
All lead-throughs raise the temperature of their surroundings. A wooden deck, in
particular, may dry due to the heat. Remember that the surface of the lead-through
is hot during use.
A exhaust gas tube with a length of more than 2 meters (7’) has to be equipped
with a drainage lock
602293
(condense water) located to the lowest point of the
tube.
The Exhaust gas pipe must be made of stainless steel.
If necessary, seal the connections between the exhaust gas pipe and the lead-
through with heat-resistant silicone.
When installing the lead-through to the stern side or to otherwise leaning position,
be sure that the water do not stuck the exhaust. Drill app. 2 mm (
3
/
32
”) hole to the
lead-through or to the exhaust pipe.
FUEL
200 mm
400 mm
500 mm
min 300 mm
(12”)
Goose neck
Safety distances
Installation to the stern side
Summary of Contents for 800 D
Page 28: ...VHQQXV IL IL 2 800 D S 490549...
Page 30: ...IL VHQQXV IL 3 800 D S 490549...
Page 63: ...QVWDOODWLRQ HQ HQ 6 800 D S 490549...
Page 64: ...QVWDOODWLRQ HQ HQ 6 800 D S 490549...
Page 66: ...HQ QVWDOODWLRQ HQ 6 800 D S 490549...
Page 100: ...QVWDOOHULQJ VY VY 0 800 D S 490549...
Page 102: ...VY QVWDOOHULQJ VY 0 800 D S 490549...
Page 116: ...6...