Electrical connections of the device
12 V direct current system
Connect the red wire of the power cord to the plus terminal of the battery and the
black or blue wire to the minus terminal. A 15 A main fuse must be installed near
the battery on the red plus wire of the power cord. See picture.
24 V direct current system
If the device is to receive power from a 24 V system, always connect a charg-
ing voltage reducer and a 12 V battery before connecting the device. Without the
battery the voltage reducer will not be enough on its own as it cannot generate the
large amount of current the glow plug requires. After the 12 V battery, the connec-
tion is the same as in a 12 V system.
24 V direct current system
Device’s quick
coupling
Jointing
A jointing should only be made in long
power cords, if necessary, in which case
the cord must be replaced with a thicker
one. The jointing cannot be more than 1
meter from the device.
Main switch
Main fuse
Power cord
Checking the connection
The device consumes most power when it is started up (glowing). At this point volt-
age losses are also at their highest. During the glowing phase, the voltage must be
at least 11,5 V measured at the quick coupling. See picture. If the voltage is lower
than this, the device may not start.
The device has to be connected to the house battery of the boat.
Installation
en
en
D10021
- 62 -
490548
800 D
Summary of Contents for 800 D
Page 36: ...fi Asennus fi D10310 36 490548 800 D ...
Page 38: ...Asennus fi fi D10190 38 490548 800 D ...
Page 40: ...fi Asennus fi D10130A 40 490548 800 D ...
Page 72: ...en Installation en D10311 72 490548 800 D ...
Page 75: ...Installation en en D10321 75 490548 800 D ...
Page 76: ...en Installation en D10131A 76 490548 800 D ...
Page 108: ...sv Installering sv D10312 108 490548 ...
Page 112: ...sv Installering sv D10132A 112 490548 ...
Page 144: ...de Einbau de D10313 144 490548 800 D ...
Page 148: ...de Einbau de D10133A 148 490548 800 D ...
Page 180: ...fr Installation fr D10314 180 490548 800 D ...
Page 184: ...fr Installation fr D10134A 184 490548 800 D ...
Page 216: ...nl Installatie nl D10315 216 490548 800 D ...
Page 220: ...nl Installatie nl D10135A 220 490548 800 D ...
Page 252: ...ru Установка ru D10316 252 490548 800 D ...
Page 256: ...ru Установка ru D10136A 256 490548 800 D ...
Page 288: ...no Installering no D10318 288 490548 800 D ...
Page 292: ...no Installering no D10138A 292 490548 800 D ...
Page 306: ...D90019 306 490548 800 D ...