FUEL
200 mm
400 mm
500 mm
en
Installation
Safety distances
en
D10121A
- 69 -
490548
800 D
Exhaust gas connections
Exhaust gas lead-throughs
Exhaust gas lead-throughs 2467, 5400 and the closable model 2460 are suitable
for device.The ø 28/45 mm lead-throughs fit the exhaust gas pipe 2448.
All exhaust gas lead-throughs are stainless steel.
General instructions for exhaust gas connections
Location
Air must always fl ow freely past the lead-through. Insta ll the lead-through on a fl
at surface. Avoid corners or recessions where wind pressure can disturb the
function-ing of the device.
The minimum distance of the lead-through from the fuel tank’s fi ller hole is 400
mm (16”).
The minimum distance of the side lead-through from the surface of the water is
500 mm (20”). Especially in sail boats it should be noted that the lead-through
must never be submerged.
It is recommended to place the lead-through in the side as far back as possible or
directly in the transom.
INSTALLATION
When preparing the installation cut-out for the lead-through, it is a good idea to
use the lead-through as a model for the cut-out; especially if the lead-through is
circu-lar. If necessary, seal the installation cut-out with silicone in addition to the
lead-through seal. Note! Do not use silicone on a wooden boat.
The side lead-through must always be equipped with a so-called goose neck sec-
tion. The goose neck will effectively prevent splash water from getting to the
device. The highest point of the goose neck must always be above the surface of
the water.
The device will go out, if the exhaust gas lead through is submerged.
OTHER THINGS TO NOTE
Exhaust gas is hot. Always ensure that there is nothing that is susceptible to heat
damage within 200 mm (8”) of the effective area of the exhaust gases (e.g.
ropes, fenders or the side of another boat).
All lead-throughs raise the temperature of their surroundings. A wooden deck, in
particular, may dry due to the heat. Remember that the surface of the lead-
through is hot during use.
The exhaust gas pipe must be made of stainless steel.
If necessary, seal the connections between the exhaust gas pipe and the lead-
through with heat-resistant silicone.
When installing the lead-through to the stern side or to otherwise leaning
position, be sure that the water do not stuck the exhaust. Drill app. 2 mm (3/32”)
hole to the lead-through or to the exhaust pipe
Mounting of the transom feedthrough
Summary of Contents for 800 D
Page 36: ...fi Asennus fi D10310 36 490548 800 D ...
Page 38: ...Asennus fi fi D10190 38 490548 800 D ...
Page 40: ...fi Asennus fi D10130A 40 490548 800 D ...
Page 72: ...en Installation en D10311 72 490548 800 D ...
Page 75: ...Installation en en D10321 75 490548 800 D ...
Page 76: ...en Installation en D10131A 76 490548 800 D ...
Page 108: ...sv Installering sv D10312 108 490548 ...
Page 112: ...sv Installering sv D10132A 112 490548 ...
Page 144: ...de Einbau de D10313 144 490548 800 D ...
Page 148: ...de Einbau de D10133A 148 490548 800 D ...
Page 180: ...fr Installation fr D10314 180 490548 800 D ...
Page 184: ...fr Installation fr D10134A 184 490548 800 D ...
Page 216: ...nl Installatie nl D10315 216 490548 800 D ...
Page 220: ...nl Installatie nl D10135A 220 490548 800 D ...
Page 252: ...ru Установка ru D10316 252 490548 800 D ...
Page 256: ...ru Установка ru D10136A 256 490548 800 D ...
Page 288: ...no Installering no D10318 288 490548 800 D ...
Page 292: ...no Installering no D10138A 292 490548 800 D ...
Page 306: ...D90019 306 490548 800 D ...