First start-up
After installation or maintenance, if the fuel line is empty, the heater may not start
at the the fi rst attempt. Start-up phase with empty fuel line is longer than normally
and might take about 15 minutes. If the heater doens’t ignite the red combustion
indicator light will start to blink after start-up.
Turn off the heater. The device cannot be restarted until the cooling phase is com-
pleted.
When the cooling phase is fi nished, switch the heater on again.
If the device does not start after two attempts, it cannot be started again: the heater
will lock itself (lights blink to indicate this). Find out the reason why the unit didn’t
start.
If the heater iginites during two attemps the red combustion indicator (1) will go on.
After locating the fault, release the locking (instructions in the maintenance section)
and start-up the unit.
Depending on the length of the fuel hose, the heater may have to be started up
several times during priming. Keep an eye on how the fuel travels in the fuel hose
while starting up the heater.
Normal Use
The power is adjusted manually. The cooker will always ignite in manual mode.
After the ignition power can be adjusted step-less with the power control (2) knob.
Avoid turning the power control knob rapidly back and forth, this may cause the
burner to become sooty.
When using as a stove, make sure that the thermostat indicator light (5) is not on.
Cooker used as a heater, thermostat use
Requires a heat blower lid (accessory).
Automatic power adjustment, thermostat controlled adjustment.
Is used only with a heat blower lid when the lid is folded over the ceramic top.
The function can be activated/deactivated whenever wanted. Turn the power cont-
rol knob (2) to positions min-max-min-max when yellow heating indicator (7) is on,
to activate the function. As a confi rmation of the mode change, the thermostat light
(5) will be lit.
When turning again the power control knob (2) min-max-min-max, the thermostat
light (5) will go off and the unit returns to manual mode.
After the cooker has passed the ignition phase, the temperature is adjusted by
turning the power control knob (2). The power control knob is turned to the required
position.
When the thermostat light (5) is bright, the temperature is below the required tem-
perature – the effect is increased. When the thermostat light (5) dims the required
temperature is achieved.
The total time of the starting procedure is app. 11 minutes, when after
the device can be adjusted or will set itself to the selected effect.
en
D30031
- 79 -
490548
800 D
Summary of Contents for 800 D
Page 36: ...fi Asennus fi D10310 36 490548 800 D ...
Page 38: ...Asennus fi fi D10190 38 490548 800 D ...
Page 40: ...fi Asennus fi D10130A 40 490548 800 D ...
Page 72: ...en Installation en D10311 72 490548 800 D ...
Page 75: ...Installation en en D10321 75 490548 800 D ...
Page 76: ...en Installation en D10131A 76 490548 800 D ...
Page 108: ...sv Installering sv D10312 108 490548 ...
Page 112: ...sv Installering sv D10132A 112 490548 ...
Page 144: ...de Einbau de D10313 144 490548 800 D ...
Page 148: ...de Einbau de D10133A 148 490548 800 D ...
Page 180: ...fr Installation fr D10314 180 490548 800 D ...
Page 184: ...fr Installation fr D10134A 184 490548 800 D ...
Page 216: ...nl Installatie nl D10315 216 490548 800 D ...
Page 220: ...nl Installatie nl D10135A 220 490548 800 D ...
Page 252: ...ru Установка ru D10316 252 490548 800 D ...
Page 256: ...ru Установка ru D10136A 256 490548 800 D ...
Page 288: ...no Installering no D10318 288 490548 800 D ...
Page 292: ...no Installering no D10138A 292 490548 800 D ...
Page 306: ...D90019 306 490548 800 D ...