SafeFlame 96 D / 97 D
1
Figure 1: Wallas SafeFlame 96 D Diesel Oven
INSTALLATION INSTRUCTIONS
Figure 4: Minimum dimensions of the space required for installation. If the oven is mounted in a closed space or covered
by a board, the cooling air opening must be reserved above the oven for air circulation, minimum 100 cm
2
.
Space Requirements
- The dimensions of the space required for installation
are illustrated in figures 4 and 5.
- Drilling cooling air holes in the bottom of the
installation opening is recommended. Collective area
of the holes should be about 30 cm
2
.
- The dimensions of the space required for installation
of the 96 D oven’s control panel are illustrated in
figure 6.
- The gimbal-mounting frame defines the amount of
space required for a gimbal-mounted appliance.
- To remove the burner unit for service, the oven has to
be removed from its position.
- The installation opening must be manufactured from
a fire-resistant material or be lined with a fire-resistant
material.
- Note that the control panel cable for the basic 96 D
is 1.5 m long.
Fuel hoses
- The maximum length of the fuel hose is 8 m; the
standard fuel hose is 4 m.
Considerations on the installation place and on its effect on the installation
Figure 2: Wallas SafeFlame 97 D Diesel Stove
Figure 3: Optional gimbal-mounting 113 for both the oven
and stove
A 4-metre long electric cable and a 4-metre long fuel
pipe with a cork and an internal filter are delivered as
standard.
- The recommended position for the fuel tank is 0.5 –
1 m below the oven.
Exhaust pipes
- The maximum length of the exhaust pipe is 4 m.
Exhaust pipe must be insulated with ø 45 mm
insulation pipe.
- The Combination lead-through may be installed into
the hull or deck.
- The hull lead-through should be situated as far aft as
possible, preferably in the stern.
- If it is possible that the deck lead-through
transiently dips under water it has to be used a
sealable deck lead-through (2460).
- Air must be allowed to flow freely past the lead-
through.
- Take care not to blow hot gases against other boats.
Important:
- You must not mount the 95D cooking range and the
96D oven to the same installation opening. 95D and
96D require an installation opening of their own.
380 mm
min. 20 mm
475 mm
min. 500 mm
360 mm
min. 530 mm
475 mm
min. 100 cm
2