Troubleshooting, undervoltage
The operating voltage in the
current connector of the device is
below 10,7 V when the unit is in a
load.
Check the the voltage of the battery.
The voltage needs to be over 12 V as
the unit is in a load.
Check the connection of the fuse in
the power supply.
Check and clean the contacts of the
connectors.
Start the engine.
The charging voltage increases the
voltage of the battery.
Check the condition of the battery
and the power cables / connectors.
Check the installation and connection
of the main power cables and the
main power switch.
Charge or change the battery.
Under 12 V
Yellow
Undervoltage
Over 12 V
4.2.2_en
Bring the device in for service.
FAULT INDICATION WITH
BLINKING LIGHTS
en
D20051A
- 72 -
XC Duo
490541G