BXTR6438
Trailer Wood Chipper
Controls
29
0:00 HOURS
ROTOR SPEED
FEED POSITION
NEUTRAL
RPM
0000
01245
01856
SETTINGS
FEED SETTINGS
RESET DEFAULTS
DIAGNOSTICS
OEM SETTINGS
Settings Menu Screen
On the
Main
screen, press the soft key below
Settings
to
open the
Settings Menu
screen. Use this screen to select a
settings option. All settings are retained when the machine is
shut down.
The Settings Menu screen includes:
•
FEED SETTINGS – Opens the Feed Settings screen
(see
) to set the maximum or minimum feed
roller speed, feed roller start speed, or minimum feed
rotor speed.
•
RESET DEFAULTS – Opens the Reset Defaults screen
(see
) to confirm that you want to return all
settings to the factory default values.
•
DIAGNOSTICS – Opens the Diagnostics screen
(see
) to see an overview of the machine
operating parameters (for example; feed roller position,
rotor speed, solenoid valve current, or current feed
settings).
•
OEM SETTINGS – Only authorized Wallenstein Equipment
personnel are permitted to access the original equipment
manufacturer (OEM) settings (see
).
Open a screen:
1.
Use the soft key below the
Up arrow
or
Down arrow
to scroll through the menu options. The active selection is
highlighted.
2.
Press the soft key below
Select
to open the highlighted
screen.
Feed Settings Screen
The
Feed Settings
screen provides access to the four main
P3 PULSE program settings. The active selection is highlighted.
The initial selection is MAX FEED SPEED.
Change settings:
1.
If required, press the soft key below the
Up arrow
or
Down arrow
to change the setting number.
2.
Press the soft key below
Select
to save the displayed
number and select the setting to the right.
3.
Repeat Steps 1 and 2 three times to change the settings, as
required, and return to
Settings Menu
screen.
01250
FEED SETTINGS
MAX FEED
SPEED
MIN FEED
SPEED
FEED START
SPEED
MIN ROTOR
RPM
0%
0%
0000
0000
Fig. 18 –
Settings Menu screen
Fig. 19 –
Feed Settings screen
01857
SETTINGS
FEED SETTINGS
RESET DEFAULTS
DIAGNOSTICS
OEM SETTINGS