6.10.1 Remove an Internal Blockage
1.
Set the machine to a safe condition.
For instructions, see
2.
Remove the upper-rotor-housing fastener, and then open
the upper rotor housing. See
3.
Engage the rotor lock.
For instructions, see
Engage the Rotor Lock on page 36.
4.
Remove material from the upper rotor housing and
discharge chute.
5.
Remove material from the lower rotor housing.
If necessary
, turn the rotor to remove material from the
lower rotor housing:
a. Disengage the rotor lock (do not close the upper rotor
housing).
For instructions, see
Disengage the Rotor Lock on page
.
b. Carefully and slowly, turn the rotor to make sure that
there is not a blockage between the rotor and ledger
knife.
Do not reach into the rotor housing while the rotor is
moving.
c. Engage the rotor lock.
For instructions, see
6.
Remove any remaining material and debris from the lower
rotor housing.
7.
Disengage the rotor lock.
For instructions, see
Disengage the Rotor Lock on page
8.
Close the upper rotor housing.
9.
Install the upper-rotor-housing fastener. See
Use a calibrated torque wrench to torque the fastener to
80 lbf•ft (110 N•m)
.
10.
Start the machine to see if the blockage is cleared.
If the machine does not operate, do steps 1 to 9 again until
the blockage is cleared.
02265
Figure 22 –
Upper-rotor-housing fastener
02264
Figure 23 –
Open the upper rotor housing
BXT36S
Wood Chipper
Operating Instructions
35
Summary of Contents for BXT36S
Page 32: ...02251 Figure 20 Set up the machine Operating Instructions BXT36S Wood Chipper 32...
Page 38: ...02249 Figure 26 Transport position Transport BXT36S Wood Chipper 38...
Page 42: ...02250 Figure 30 Storage position Storage BXT36S Wood Chipper 42...
Page 71: ......