Revision 7 

22 

operated by pressing the button at the rear cover next to the illuminated mains 
switch. Press the soap prime button until soap begins to consistently dispense 
from the basin nozzle. 

  Soap levels should be checked periodically depending on usage to maintain 

efficient operation of the unit. The system should be washed through with 
warm water periodically to remove any solidified soap within the tubing & 
nozzle as follows: Remove the soap tube from the soap container, place the 
free end of soap tube into a beaker or container of WARM water & using a 
continuous press of Soap Prime button, flush WARM water through the 
system. 

 

11.4 Water Temperature & Flow 

 
NOTE: Due to the anti-ligature design the basin area is relatively shallow. The 
flow rate of water is therefore regulated to a low level to avoid water over 
spilling the basin lip. 

  The hand wash water temperature is governed by the flow rate which is set by 

a flow regulator built into the water system at a rate of 1.8LPM. This flow rate 
may slightly vary due to the water supply pressure and tolerance of the 
regulator. 

  Water temperature can also be affected by changes to the ambient 

temperature of the incoming cold supply which may happen seasonally 
depending on the nature of the water supply. 

  The cold water outlet if fitted is also fitted with a flow regulator (0.8LPM). 

11.5 Maintenance 

 

  Wallgate operates a comprehensive spare parts service. Contact our service 

department for all spare part & servicing requirements. 
 

WARNING: IN MODELS WITH A WATER HEATER) THE WATER HEATER IS A 
VENTED TYPE AND IN NO CIRCUMSTANCES MUST THE WATER OUTLET 
NOZZLE BE ALLOWED TO BECOME BLOCKED OR CONNECTED TO ANY PIPE 
OR TAP. 
 

  The unit basin fascia must be cleaned with non-abrasive cleaners only, use 

abrasive washbowl cleaners such as standard domestic cleaning products 
dependent upon the level of soiling. Proprietary de-scaling agents may be 
used to remove lime scale from the bowl, and the water nozzle. 

  From 

a user’s point of view, the most important care items are: 

Summary of Contents for PSH-20 Series

Page 1: ...Product Manual Model PSH 20 series Hand Wash Dryer ...

Page 2: ...Revision 7 2 Product Manual PSH 23 ...

Page 3: ...n 8 10 4 Cabinet Preparation and Fitting 9 10 5 Water Supply Connection 10 10 6 Electrical supply connection 11 10 7 Soap Liquid Fitting 12 10 8 Commissioning for Use PSH Control Cabinets 12 10 9 Commissioning for use WDC100 200 Control Units Error Bookmark not defined 10 10 Technical Specifications 13 11 User and Maintenance Instructions 20 11 1 Introduction 20 11 2 Operation 20 11 3 Replenishing...

Page 4: ...rmation about hazards that can cause injury or death Read and understand these warnings before you install and commission the CWC water closet Failure to heed these warnings can have serious consequences WARNING This is a warning 4 Note A note with black text on a yellow background is used to draw your attention to important and useful information NOTE This is a note 5 Numbered procedures Steps in...

Page 5: ...ed in the ALS_180_IR to operate the hot and cold water taps Operate the sensor switch by holding your hand within 50mm of the sensor BSP The British Standard Pipe BSP thread is a family of standard screw thread types that has been adopted internationally for interconnecting and sealing pipe ends by mating an external male with an internal female thread 1 Push fit Push fit type fittings are a plumb...

Page 6: ...extremely safe in cell hand wash solution It includes integral soap dispenser instantaneous warm water heater an optional cold water outlet and warm air hand dryer all managed integrally An optional plug in module for WC flush is available ...

Page 7: ...p air hose and pneumatic water valve NOTE The PSH 23 model series that use a WDC electronic control unit sold separately as an option are detailed in the PSH 23 product manual 10 2 Site Preparation Prepare an opening in the wall surface accurate to the dimensions shown on the installation drawing provided with the product It is important that the aperture is square and within tolerance to the stat...

Page 8: ...RH position a blank bezel plate to be fitted with either a plain plate or a plate with legend NOT DRINKING WATER For reference the bezels and operating button can be removed by undoing the large flanged securing nuts from the back of the fascia When refitting the retaining nuts tighten to a torque of 13 Nm Cold water outlet models At the front top LH basin fascia position is fitted 2 stainless ste...

Page 9: ...flange around the top of duct must fully engage onto face of horizontal plate as shown Depending on the wall thickness the importance of the metal air duct fitting correctly the duct may require cutting to the correct length A template with cutting instructions is supplied with the product Drawing number INS_PSH_20 DUCT TEMPLATE Installation into walls less than 128mm thick Mount the basin fascia ...

Page 10: ...lle spigot on the top of the basin Consideration should be given to making this as short a distance as possible it is recommended not to exceed a 1 metre path length of flexible duct when installing flexible duct avoid the following the flexible air duct should be curved as gently as possible and sharp 90 turns should be avoided Extending the flexible air duct to any longer than 1 metre with tight...

Page 11: ... fits on the top of the basin Connect other end of hoses as follows viewed from the rear of the basin the LH basin nozzle hose to loop round connect to the RH cabinet push fit elbow the RH basin nozzle hose loops round connects to the LH cabinet push fit elbow Waste connection The basin includes a waste outlet pipe tail connection of 1 40mm size It should be terminated to a suitable deep seal wast...

Page 12: ...provided Hang a full soap container 2 5 or 5ltr onto the soap bracket Place the tube with bung attached into the bottle push fit the plastic bung into the bottle neck 10 8 Commissioning for Use PSH Control Cabinets With the cabinet cover removed fully open the water inlet taps on the unit located under the cabinet Check all plumbing connections to the unit for any leaks then refit the cover If rel...

Page 13: ...2 Water Supply Minimum pressure 2 Bar Static Maximum pressure 3 Bar Static Supply pipe size 15mm copper Waste connection 1 40mm pipe for connection to 1 trap Trap not supplied Power supply 230V AC 50 60Hz 13 Amp single phase Power rating Maximum power rating 3000 W Weight 36kg Dimensions 200mm W x 150mm H x 80mm D Enclosure IP Rating IP20 Regulatory compliance Complies with RoHS LVD 2006 95 EC and...

Page 14: ...Revision 7 14 ...

Page 15: ...Revision 7 15 ...

Page 16: ...Revision 7 16 ...

Page 17: ...Revision 7 17 ...

Page 18: ...Revision 7 18 ...

Page 19: ...Revision 7 19 ...

Page 20: ... button Option will operate the WC cistern flush valve followed by a timed cistern fill Your installer will have passed to you this product manual which includes the installation commissioning instructions The unit basin fascia is manufactured in a tough polyester solid surface material in white granite effect colours Small variations in colour may occur from one unit to the next 11 2 Operation Th...

Page 21: ...itself must not be removed from the cabinet except by qualified personnel due to the RISK OF ELECTRICAL SHOCK Moving the panel to the right will expose the Controller Interface Module Full instructions for adjusting air and water time cycles and lockouts are given in document INSTALLATION SETUP MANUAL TCU100_1 After all adjustments are completed ensure that the small cover is replaced over the Con...

Page 22: ...hich is set by a flow regulator built into the water system at a rate of 1 8LPM This flow rate may slightly vary due to the water supply pressure and tolerance of the regulator Water temperature can also be affected by changes to the ambient temperature of the incoming cold supply which may happen seasonally depending on the nature of the water supply The cold water outlet if fitted is also fitted...

Page 23: ...n 11 3 o On models with soap dispensing check the soap level regularly only use recommended soaps o On models with warm air drying have the motor brush wear checked periodically by a qualified electrician Depending on usage LOW per 2 years HIGH once a year typically Any service repair work must be carried out by a qualified engineer which during the warranty period must be a Wallgate engineer or a...

Page 24: ...Revision 7 2 Wallgate Ltd Crow Lane Wilton Salisbury Wiltshire SP2 0HB England tel 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com ...

Reviews: