Security: If the water temperature in the Walltherm
®
reaches a temperature higher than
90°C the el. air flap closes automatically and remain closed until the water temperature
cools down to 80°C. In this case the screen becomes red and you can read the
information: Water temp. too high!
In case of electricity cut the el. air flap closes automatically and the stove will not be
provided with combustion air, the fire chokes. When the electricity return you have to push
the start button (2 seconds) to reopen the el. flap.
Wiring of the WAL03 depending on your system:
Wiring of a system with Walltherm
®
and storage tank
B1 – storage tank
F1 – Walltherm
®
boiler
stove
R2 – pump boiler stove (no PWM!!)
R3 – el. air flap
T1 – sensor water Walltherm
T2 – sensor lower storage tank
(Sensor position: lower storage tank but
higher than the return flow of the boiler
stove)
T4 – sensor fume temperature
Walltherm
®
(red cable)
T5 – sensor higher storage tank
Important:
The regulation WAL03 can only work with high
efficiency pumps without PWM)
El. air flap function:
(if installed):
Before the Walltherm
®
gets lighted you have to
push the start button for 2 seconds. Then the el.
air flap opens for min. 2 hours and remain open
until the water temp. in the Walltherm
®
cools
down under 40°C.
On the display you can always control the