WALLTHERM
®
produced and developed by
Walltherm
®
46/64
5.c Loading wood logs
Turn the lever of the exhaust fume flap to
position OPEN:
(lever has to pointing down - position OPEN)
Just open the door of the upper combustion chamber, if the wood is burned
down and there is only ember.
Open the door slowly.
Please check the buffer tank temperature before filling the burning chamber and
insert only as much wood as the buffer tank is able to take up and to convert into
energy.
It’s necessary to have a layer about 3 – 4 cm of ember otherwise you have to
create it again with some wood logs.
Then put the wood logs compactly in the upper combustion chamber. There must
be a layer of wood and no hollow space.
After putting in the wood logs the exhaust gas temperature should be about 300 -
400 ° C and the chimney should have enough natural drought and the gasification
flame can be activated.
To activate the gasification flame again close the exhaust fume flap:
Turn the lever of the exhaust fume flap to position CLOSED:
(lever in horizontal position - CLOSED)