WALLTHERM
®
produced and developed by
Walltherm
®
52/64
The cleaning of the flame wall is very important to guaranty a proper work.
Keep the flame wall free of ash! A dirty flam wall reduce the draft of the chimney and the
performance of the stove.
The gaps need to be free! If necessary to put out the flam wall, you need to lift the injector
block and then take it out with the fireplace poker!
Flam wall with gaps injector block
(openings to doorside)
edge/stop
Information: The flam wall can move during the transport of the stove. We
recommend to check the position of the flame deviator and if necessary to adjust it. Push
it back into the lower combustion chamber until it gets in contact with an edge (stop) which
is on the top.
A few times you should clean the air supply sheets for the glass cleaning system
(upper combustion chamber):
To prevent the glass from the upper combustion chamber to get black you need to clean
the air supply right behind the upper door (stainless steel sheets, see pictures below)
air supply sheets
Clean this spaces
from ash, than the
air supply for the
glass cleaning of the
upper and lower
combustion chamber
works correctly.