The function of the electrical air flap:
Before lighting the boiler stove you push the “start” button on the controller WAL03 which
opens the air flap for minimum 2 hours. Now combustion air can stream to the stove. After
the 2 hours the flap remains open if the water temperature (heat exchanger) in the boiler
stove is higher than 40°C.
The flap will close if the water temperature falls down under 40°C.
More information about the system you find in the manual of the controller WAL03
and in chapter 4.f
Electrical air flap for installation in the air
channel
(
2 x Ø125 mm)
Electrical air flap with flange for the
installation on boiler stoves body
(1 x
Ø125 mm + 1 x flange)
Info: We can deliver two types of the electrical air flap.
The standard el. air flap for installation in the air channel should be
installed as nearest as possible to the air inlet. The el. air flap with
flange can be installed on boiler stoves backside or bottom. Look
pictures.
Controller WAL03
with electrical air
flap
Electrical air flap