Protection stone lower combustion chamber:
To protect the door glass of the gasification flame and it´s high temperatures (up to
1000°C) we position the protection stone behind the door in the lower combustion
chamber.
In the lower combustion chamber you find an edge (stop) which indicates the protection
stones position:
edge (stop) protection stone correct position
7 Maintenance
Only authorized personal are allowed to do the maintenance for the
water parts and electric parts. See chapter 2.a and 2.c.
7.a Doors
The boiler stove must never be operated with open doors. Eventually out coming
glowing materials can cause fire.
Before opening the doors please open the exhaust fume flap so the smoke is taken up
gradually through the chimney and cannot escape through the door. The doors should
only be opened when the fire turns out and you want to put some more wood on it. If
you have to open the doors during the burning phase please try to do so very slowly and
carefully. Sparks and fire can possibly come out.
Attention: Do not forget to close the fume flap after loading the stove with wood