progress & innovation
Vers. 12.1
34
/
46
High efficiency pump Ecocirc:
- max. power 23 Watt
- Spinning the lever on the pump to 0 will
change the backlight color and the
operating mode of the pump
- For use with the walltherm the pump
should be in standard mode where the
LED is white, not blue!
Lever
White LED = manual control of the pump speed
Blue LED = automatic pump speed control by differential pressure
Information to the exhaust gas temperature:
Normally the exhaust gases of the Walltherm®
reach a temperature of around 120 – 150 °C.
Because of this low exhaust temperatures, a lot
of people are worried about problems with the
chimney.
These worries are unjustified: When you light
the fire, the exhaust fume flap 5 is open and
really hot exhaust gases enter the chimney. In
this phase the temperature reaches 200 – 400 °C
and the chimney will dry out and warm up.
After this phase, as soon as the chimney is warm, you can close the flap (5) and the
temperature of the exhaust gasses will lower to 120 – 150 °C. Thanks to the perfect
combustion, the exhausts are really clean and will not cause problems inside the
chimney.
When the exhaust temperature sinks lower than 110 °C, this is a sign that the drought is
too low, please change the following:
Open the cover which is behind the chimney exit on the top of the stove.
This gives you the possibility to create a by-pass for the exhaust gases.
Please see the description below how to activate this by-pass, as a result, a part of the
heat exchanger is deactivated and as a result the exhaust temperatures rise by 10-20°C.