Cartoon box or Wood base removal: using a hammer, tilt the cabinet to one side and loosen
the two thread-forming screws, drag the cabinet from the back side holding the base still until
the four castors have gone out from the containing holes, slightly tilt the cabinet backward and
take the base away pulling it from the front side.
Use gloves when handling the 3 Waves cartoon box or the wooden base to protect the hands
from splinters.
Position the equipment with the help of a level. Remove the protective PVC film from the
external surfaces of the unit.
2.3 WIRING AND ELECTRICAL HOOK-UP
Receptacle installation and electrical wiring operations must be performed by a qualified
electrician. For safety reasons adhere to the following indications:
Check that the electrical plant is suitably sized for the absorbed power of the unit.
If the electrical socket and the plug on the equipment power cord are incompatible, call
technical service or your local distributor.
Do not use reductions or multi-way adapters
It is important to connect the equipment correctly to an efficient earth system executed
in compliance with the relevant legislation.
A switch or circuit-breaker must be included in the installation:
it must be suitably located and easily reached;
it must be marked as the disconnecting device for the equipment.
2.4 SET UP OPERATIONS
To avoid errors and accidents, perform a series of checks for possible damage sustained during
transport, installation and hook-up operations before starting up the unit.
PRELIMINARY CHECKS
Check the condition of the power cord (no cut or chaffing). Check that the door hinges and
shelf support are stable.
Check the door seals and shelves are not damaged (broken or scratched) and that the door
closes and seals properly.
Make sure all copper tubing, unions are in perfect condition.
FOR OPTIMAL PERFORMANCE
Do not block the motor compartment air vents. Do not lay objects on the top of the equipment
Before storing products wait until they are cold.
Arrange the products on suitable shelves or in containers. Do not place products directly on
the base or against the walls, doors or fixed guards of the unit.
Make sure doors are kept closed.
Keep the defrost water drain outlet clear.