Cycle Counter Installation Instructions
EO7804
80101564 12/15 Rev 03
•
IMPORTANT!
Disconnect battery power supply.
•
Review these instructions before beginning. Locate a position on your liftgate for the cycle
counter. Be certain that location will not interfere with liftgate operation and is in a relatively
protected area. Refer to diagrams shown for suggested locations if required.
•
Make certain wires will reach connections on pump unit.
•
See below for hole size and pattern required for mounting counter, if required.
•
Locate and drill two mounting holes as shown, if not already present. Take necessary
precautions to prevent metal shavings from contaminating the hydraulic system.
•
Mount cycle counter bracket using two #6-32 screws and lock nuts.
•
Connect ground wire of cycle counter to ground stud.
•
Connect red wire from cycle counter to wire adapter, and connect other ends of wire Adapter
between lowering valve coil and control switch wire.
FOR WDV: Connect red wire from cycle counter to wire adapter, and connect ring terminal
end of wire adapter to S3 valve.
•
Loosely bundle and wire tie slack wires as needed.
•
Re-connect battery power supply and operate liftgate to test.
GR02891
GR02824
1
1
8
1
13
16
DRILL
3
16
DIA HOLES