Chapter 1 Safety Information
80101253 Rev 04 EO 6309JJ
Liftgates with Tilt Function
•
Proper use of the Control Switches is of extreme importance.
•
Improper use of Tilt Switch could cause load to fall from the Platform or damage the liftgate.
•
Platform should be in a generally horizontal position when raising or lowering with a load.
•
In any tilt position, the Platform may vary from level while raising or lowering the Platform.
Liftgates equipped with spring operated Cam Closer
•
Replace Cam Release Spring every five (5) years or 15,000 cycles, whichever comes first.
RGL-Series Liftgates
•
Make certain Platform Brake mechanisms are operating properly.
•
The Runners are always to remain powered up against the Upstops Pins when in transit.
•
Inspect Cables every three (3) months or 750 cycles, whichever comes first. Cables must be replaced if they
show signs of wear, distortion, kinking or if any broken wires are visible
•
Replace cables every five (5) years or 10,000 cycles, whichever comes first.
This is the safety alert symbol. This manual uses this symbol to alert you to potential personal injury
hazards.
Obey all safety messages that follow this symbol to avoid personal injury or death.
SIGNAL WORDS
WARNING
Indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
Black letters on an orange background
CAUTION
Indicates a potentially hazardous situation, which if not
avoided, may result in minor or moderate injury. May
also be used to alert against unsafe practices.
Black letters on a yellow background.
NOTICE
Indicates a potentially hazardous situation, which if not
avoided, may result in property damage.
NOTICE
WARNING
CAUTION