Troubleshooting
51
EN
In the unlikely event of a fault, do not send the welder to us without speaking to us beforehand. A
short telephone call and a short description of the fault is usually enough to identify the cause of
the problem. In most cases problems can be resolved with a correct replacement part, which we will
send to you as quickly as possible.
This prevents unnecessary costs for all parties involved.
You can find our service contact details on the back of this operating manual.
Troubleshooting
Technical data
Problem
Possible cause
Rectification
Not working.
No power.
Get the mains fuse or the mains
connection checked by a technician.
Overload protection has tripped,
overload indicator 8 is on.
Allow the welder 1 to cool down.
Poor weld.
Welding current setting too low or
high.
Check the welding current setting.
Check the correct polarity of the
electrode holder 14 .
Welding current
too low.
Poor earth connection.
Check the welding cable with earth
terminal 15 .
Contact the service centre if necessary.
Model
WWS-120B2-K01
Mains connection U
1
230 V~ (alternating current) / 50 Hz
min. fuse
16 A (slow blow)
Welding current I
2
20 A - 120 A (MMA)
Open circuit voltage U
0
70 V
Working voltage U
2
22.6 – 24.8
Electrode diameter:
MMA: 1.6-2.5 mm
Protection category
IP21S
Isolation category
H
Cooling mode
AF
Weight
3.1 kg approx.