38
9
Disposal of Cleaning / Servicing Substances
Disposal of any such substances must be in accordance with all applicable local
and national regulations, directives and laws.
Warning
Pay special attention to all processing specifications and warnings issued by the
manufacturer of spraying and cleaning media. The improper disposal of any toxic
waste material represents a serious thread to to environment, i.e. to the health of
mankind and animal life.
10
Specification Data
Weight:
500 g
Connections:
Atomizing Air
G 1/8“
Control Air
M 5
Material Inlet
G 1/8“
Pressure Ranges:
Atomizing Air Pressure
see table
Control Air Pressure
max. 6 bar
Material Pressure
max. 6 bar
max. Operating
Temperature
of Spray Gun
80° C
Sound Level
(measured at a distance
of 1 m from the spray gun)
83 dB(A)
Air Consumption:
1 bar Atomizing Air Input
20 l / min.
2 bar Atomizing Air Input
30 l / min.
3 bar Atomizing Air Input
40 l / min.
4 bar Atomizing Air Input
50 l / min.
5 bar Atomizing Air Input
60 l / min.
6 bar Atomizing Air Input
80 l / min.
Right to effect technical changes reserved.