40
9
Disposal of Cleaning / Servicing Substances
Disposal of any such substances must be in accordance with all applicable local and
national regulations, directives and laws.
Warning
Particular attention is drawn to all processing specifications and safety warnings
issued by the manufacturers of spraying and cleaning media. Remember: The
improper disposal of any toxic waste material represents a serious threat to the
environment, i.e. to the health of mankind and animal life.
10
Specification Data
Weight:
920 g
Connections:
Atomizing Air
G 1/4“
Control Air
G 1/4“
Material Inlet
G 3/8“
Pressure Ranges:
Control Air Pressure
max. 8 bar
Material Pressure
max. 10 bar (WA XV)
max. 15 bar (WA XV needle-pull / WA XV-HVLP)
Atomising Air Pressure
see table
max. Operating Temperature
of Spray Gun
80 °C
Sound Level
(measured at a distance of
1 m from the spray gun)
86 dB (A)
Air consumption (six-bore air cap):
1.0 bar Atomizing Air Input
8.2 m
3
/h
2.0 bar Atomizing Air Input
12.1 m
3
/h
3.0 bar Atomizing Air Input
16.0 m
3
/h
4.0 bar Atomizing Air Input
20.1 m
3
/h
5.0 bar Atomizing Air Input
24.0 m
3
/h
6.0 bar Atomizing Air Input
28.0 m
3
/h