5.0 INSTALLATION AND FIXING
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
31
OPERATING MODE
FUNCTION
KEYS TO BE
PRESSED
DEACTIVATION PRESSURE
P
1
ACTIVATION PRESSURE
P
2
T
WORK
P
3
T
PAUSE
P
1
+P
2
ENTER PROGRAMMING
PROCEDURE
P
2
+P
3
PROGRAMMING MODE
DOWN
P
1
UP
P
2
ESC
P
1
+P
3
ENTER
P
2
+P
3
Operating principle
When connected electrically and mechanically to the control panel, the MDPE reads the pressure differential
value between the 2 inputs of the transducer and displays it in millimetres of water column on a 3-digit display.
At the same time the value indicated is transmitted proportionally to the 4-20 mA analog output.
Enabling timer panel operation
If the MDPE panel is set to control the timer panel, the pressure differential measuring device will prevent the
working of the cycles until the pressure read by the transducer reaches the preset
activation value
(upper
threshold). The flashing display will indicate the enabling. Once the cycle is enabled, the MDPE will disable
it when the pressure measured drops below the preset
deactivation value
(lower threshold). The display no
longer flashes.
Danger - Warning
The activation threshold cannot be set lower than the deactivation threshold.
Operating and programming mode
The programming system consists of three keys P1, P2 and P3 and the 3-digit display. The P1, P2 and P3 keys
can be used to display a certain parameter, modify the value and save the setting.
The functions that can be associated with the pressing of individual keys or combinations of keys are listed in
the following Tables:
Operating mode
5.7 Electronic control panel: MDPE setting
During normal operation, the
MDPE
panel displays the pressure value measured in real time. Pressing
P1
(DOWN) in this situation will display the preset
deactivation value
(pressure value at which the MDPE deac-
tivates the cleaning cycle), while pressing
P2
(UP) will display the preset
activation value
(once reached this
pressure level the MDPE activates the cleaning cycle).