5.0 INSTALLATION AND FIXING
2
FIL.SILOTOP_zero.--.M.A4.0722.EN Issue: A4
07.22
22
The compressed air must be:
1) Clean:
with no residues that might damage the filter.
Danger - Warning
Drain the piping prior to connecting the compressed air to the filter.
2) De-moist
- The air tank is provided with a condensate drainage tap. The user should provide for a conden-
sation separator.
3) Oil-free
-The presence of oily substances in the air could cause premature and irreversible clogging.
Use only filters that maintain the air always clean and oil free.
Tank inlet pressure
- Minimum 4 bar
- Maximum 6 bar
Variations in the conditions of use could require:
- Modifications of inlet pressure to the tank
- Modifications to the electronic board settings, which therefore vary the compressed air consumptions.
It is recommended to install a Kit (pressure gauge, air/oil pressure reducer) near the filter. A manual On-Off
device (ball valve or similar) must be inserted on the air supply line to facilitate the maintenance operations.
The required air quality must be equal to or over class 4 according to ISO 8573-1.
5.5 Pneumatic connection
Class
Maximum oil
concentration
Maximum
particle
size *
Maximum
concentration **
Maximum
condensation
point under pressure
(mg/m
3
)
[µm]
(mg/m
3
)
°C
°F
1
0.01
0.1
0.1
-70
-94
2
0.1
1
1
-40
-40
3
1
5
5
-20
-4
4
5
15
8
3
37.4
5
25
40
10
7
44.6
6
--
--
--
10
50
7
--
--
--
Not Specified
* The particle size depends on the filtration ratio ßµ = 20.
** At 1 bar (14.5 psia), 20°C (65°F) and a relative vapour pressure of 0.6 (60%).