5.0 INSTALLATION AND FIXING
2
EXT.SBB-HFF.--.M.A.0219.EN Issue: A
02.19
37
SBB-HFF
5.6 Installing the accessories
Danger - Warning
THE CUTTING KIT MUST BE USED EXCLUSIVELY ASSEMBLED TO THE FIBC DISCHARGERS SBB.
NEVER USE THE CUTTING KIT FOR OTHER APPLICATIONS.
CUTTING KIT SBB ASSEMBLY INSTRUCTION
5.5 Commissioning
Preliminary checks
After having finished and compressed air connections, carry out the following checks:
- Ensure that the pressure supply is between 4 and 6 bar.
- Check all nuts and bolts and locks to ensure they are locked perfectly.
- Check all elements to ensure they are fixed properly to the seal frame.
- Check the seals to ensure they are not damaged.
- Ensure that the warning and instruction signs are present.
- Check the piping connected to the filter (if these are present) to ensure they are fixed and assembled carefully.
Summary of Contents for SBB 125 C
Page 57: ......