SEPCOM
®
Vertical
8.0 REPLACEMENT OF PARTS
2
SEP.SEPCOM_Vertical.--.M.A4.0722.EN Issue: A4
07.22
45
5)
Remove the engineering polymer section.
Remove the worn or damaged sections and repeat the steps priorly mentioned in reversed order.
Prior to replacing the sections, clean them as well as the inside of the microfilter.
Prior to inserting the sections, lubricate the shaft.
Replace the section according to the indication in the figure below.