36
Flue channel partly blocked
Call a qualified technician
Smoke coming out of
stove
Fire chamber door is open
Shut the door
Not enough draught
Get the chimney inspected by local
heating authority
Incorrect settings
Look up sections “Use” and “Fuel”.
Dirt in stove
Clean stove and the pieces con-
necting to the chimney
Table 3
4.
Technical data
4.1
Data
All information provided by the exhaust gas values are based on the EN 12815 under stationary labor-
atory conditions. We reserve the right to make changes which relate to technical advances and / or to
an improvement in quality. We accept no liability for printing errors and changes which occur after
printing.
Model number
M80 / M90
Nominal heat load
6 kW
Space heating ability in m³ in favourable / less favourable /
unfavourable
conditions according to DIN 18893/TABLE. 2
Short-term heating
144
84
58
Exhaust gas for fuel:
Exhaust gas mass
Exhaust gas connector temperature
Flow pressure at nominal heat load
Particles / dust (based on 13% O2)
CO (based on 13% O2)
OGC (based on 13% O2)
NOx (based on 13% O2)
Efficiency
Firewood / Lignite
7.0 g/s
195
˚C
12 Pa
≤ 40 mg/m³
≤ 0.
10 %
≤ 1250 mg/Nm
3
≤ 120 mg/N
m
3
≤ 150 mg/Nm
3
≥ 8
1 %
Mains current
Bulb
230 V AC
15 W