From the “Standby” mode press “Menu OK” once: Selection of the operation mode. Using
↑↓
, the
appropriate mode of operation could be selected and confirmed with “Menu OK”.
NORMAL HEATING MODE – MANUAL
Step
Description
Display menu
After successful ignition cycle, the stove is preset in
manual
heating mode
(e.g. “man 04”).
The current output level is displayed.
The following settings are possible during the heating mode:
↑↓
± level 1-10 = 30-100% heat output.
Upon adjustment of more than 1 level, the output is adapted in a
continuous manner.
Example
↑↑↑
NORMAL HEATING MODE – ROOM TEMPERATURE CONTROLLED
Step
Description
Display menu
The stove automatically maintains a constant room temperature
and adapts to the output level (e.g. “room 56”).
If the set room temperature is exceeded even in case of lower
output levels, the stove works in intermittent ON/OFF operation
mode.
Temperature value is shown.
Level 56 corresponds to approx. 21°C room temperature.
Adjust the target temperature within a range of 1 to 100 using
↑↓
.
Example
↓↓↓↓
NORMAL HEATING MODE – TIME-CONTROLLED / MANUAL
Step
Description
Display menu
The stove heats at the preset times (max. twice a day) with a
preset output (e.g. “time 07”).
The stove is in “Standby” mode apart from these heating periods.
During the heating mode, the following settings are possible:
↑↓
± level 1-10 = 30-100% heat output.
Upon adjustment of more than 1 level, the output is continuously
adapted.
Example
↓↓↓
NORMAL HEATING MODE – TIME-CONTROLLED / ROOM TEMPERATURE-CONTROLLED
(with integrated temperature sensor)
Step
Description
Display menu
The stove maintains a constant temperature at the set times and
automatically adapts the output level.
The stove maintains the set-back temperature apart from these
heating periods.
Temperature value is shown.
56 corresponds to approx. 21°C room temperature.
Adjust the target temperature within a range of 1 to 100 using
↑↓
.
Example
↓↓↓↓
NORMAL HEATING MODE – with external room thermostat
Step
Description
Display menu
The stove is operated in the manually preset heat output level
according to the regulation of the external room thermostat.
Adjustment of the set temperature is possible only on the external
thermostat. The setting of the heat output level is done using
↑↓
.
Auto 56
Auto 72
Raum 56
Raum 72