Cleaning of the ash collector
Opening (unlocking) the lower lining
Unscrewing of the cover
Vacuum cleaning of the
cold
ash
Assemble densely in reverse order
7.3
Cleaning of the burn pot
Opening of the stove door
Removal of the burn pot (in cooled state)
Vacuum cleaning of the burn pot and firebox
Insertion (and locking) of the burn pot
Closing the stove door and proceed to other operations
Note / important:
Also remove the
connection component to the chimney
and
clean
with the brush. If the
connection component is contaminated with ash and soot, the result of service / cleaning cannot
be checked since the flue gases cannot be examined according to the specifications.
7.4
Inspection of the air suction pipe
The air suction pipe should be freely accessible.
Moreover, no dust or dirt or poisonous and corrosive vapours may be sucked in.