WANDERS Metaalwerken B.V. in Netterden, the Netherlands, gives a five-year guarantee for your gas fireplace
after the purchase date, provided that the fireplace is properly installed and used in accordance with the
instructions in this manual. The guarantee includes all defects which can be reduced to flaws in material and
construction, in which case you will receive the new parts free of charge. Labour costs or other expenses are
not covered by the guarantee. You can send defect parts (carriage paid) to WANDERS Metaalproducten B.V.,
Amtweg 4, 7077 AL in Netterden [The Netherlands].
The guarantee does not include: failure due to improper use; non-compliance with the installation and
operating instructions; installation by a non-certified installer; negligence of the apparatus and converting
the hearth to be fired with another kind of gas.
WANDERS cannot be held responsible for any cracks in stuccoed walls or discolouration of walls, ceilings and/
or grates after burning the fireplace. Discolouration is caused by dust particles burning in the convection
cover. To reduce the chance of cracks in stucco and to minimize discolouration we refer to the advice given for
decorative hearths. Your installer can give you more information.
Any complaints will be dealt with after the sales firm, the installer or the gas company has filed a complaint
and sent a copy of the purchase receipt with purchase date. Any repairs do not entitle you to extend the
guarantee term. All consequential damages or loss are excluded.
Installation instructions
Your gas hearth must only be installed by a certified installer in combination with WANDERS’ concentric pipe
system. Only then will the hearth be approved according to the European CE standard for gas appliances. We
will not give any guarantees if the gas stove is fitted and/or installed in an incomplete or improper manner.
The flue has an inside duct 100 mm in diameter and an outside duct 150 mm in diameter. Flue gases are
discharged by natural draught to the outside air via the 100mm inside duct, while combustion air is supplied
between the 100mm and 150mm channels.
The appliance may only be installed and connected by a certified installer in accordance with the standard
gas installation instructions and the installation requirements mentioned below. Furthermore, the national
and local rules and regulations on placing and using closed gas appliances shall be applicable. Only a certified
installer has the authority to change the setting values (in accordance with the requirements) and to carry out
any other adjustments.
Before installing the appliance, the installer must check whether the information on the type tag of
the fireplace corresponds with the gas type and gas pressure to which the appliance is connected. If it
does not match, you are not allowed to connect the gas hearth.
Placing
The gas fireplace can be placed in a crack-free and/or mechanically ventilated home without difficulty. There
is no need for extra ventilation for combustion or for a smoke and fire vent. Waste gases are discharged by
natural draught via the inner pipe into the open. The oxygen needed for burning the fire is supplied from the
space between the pipes. This is the reason that no insulation must be placed between the inner and outer
pipe.
!