Flue gas values in accordance with DIN 4705, DIN 18895 part 2
When door is closed
logs
Flue gas quantity
8.4
g/s
Flue gas temperature
290
˚C
Pre-pressure
0.12
mbar
Yield
78.9
%
CO at 13% O2
0.07
%
Particulate
matter
26
mg/m3
Certificate Institute 1625. Test standard EN 13240. Test report no. RRF-400169
Target value for the volume of the space to be heated:
Not all spaces meet the present insulating values. According to DIN 18893, the following values can be taken for
the volume of the space to be heated:
If heating circumstances are favourable:
Calculate according to DIN 4701
In less favourable circumstances:
135 m3
In unfavourable circumstances:
95 m3
For temporary heating you may assume a reduction of 25% for the volume to be heated if the interval is more
than 8 hours.
Protection of the wall
Walls made of combustable construction parts
Supporting walls in steel construction
Intergrated pieces against stove
Intergrated pieces in the wall behind
Other walls
Wall thickness < 10 cm
Wall thickness > 10 cm (e.g. a brickwork wall)
Table for thickness of insulation cf thickness of the wall
Wall thickness
10 cm
X
X
X
X
X
-
Insulation
back side
8 cm
on the side
8 cm
under side
6 cm
Convection
house
X
X
X
X
X
-
Ÿ
Table gives the insulation thickness to be used for a given wall thickness to protect intergrated wall.