28
Technical details Kanda
Technical details
KANDA 70
KANDA 85
Door latch
Ba
I/II
Ba
I/II
Nominal capacity*
9
kW
9
kW
Diameter tube for combustion gases
200
mm
200
mm
Maximum lumber supply in the stove
4
kg
4
kg
Maximum brown coal supply
-
kg
-
kg
Volume of the combustion chamber
0.12
m3
0.15
m3
Surface bottom of combustion chamber
0.17
m2
0.23
m2
* The nominal heat of 9 kW is obtained with a chimney draught of 0.12 mbar
Fuel, wood logs, 30 x 10 cm
Maximum supply
3 pieces
Primary air valve
max.
Secondary air outlet
max.
Fuel burning period
about 1 hour
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
KANDA 70
KANDA 85
When door is closed
logs
logs
Flue gas quantity
9.3
g/s
7,5
g/s
Flue gas temperature
310
˚C
285
°C
Pre-pressure
0.12 mbar
0.12
mbar
Yield
78.4
%
82.3
%
CO at 13% O2
0.10
%
0.11
%
Particulate matter
37
mg/m3
31
mg/m3
Certificate Institute 1625. Test standard EN 13229. Test report no. RRF-29 08 1767 (Kanda 70)
RRF-29 09 1965 (Kanda 85)
Summary of Contents for KANDA 100
Page 15: ...15 NL...
Page 16: ...16 User s Guide and Installation Manual Kanda GB...
Page 26: ...26 Illustration 5 Survey of the inbuilt Kanda mm...
Page 31: ...31 FR Mode d emploi et instructions d installation Kanda FR...
Page 42: ...42 Figure 5 Aper u encastrement Kanda mm...
Page 45: ...45 FR...
Page 46: ...46 Gebrauchsanweisung und Installationsvor schriften Kanda Holzofen DE...
Page 62: ...62...
Page 65: ...Technische tekeningen Technical drawings Dessins techniques Technische Zeichnungen 65...
Page 66: ...66...
Page 67: ......
Page 68: ......