21
GB
Switching from ºC/24-hour to ºF/12-hour indication
•
Press the
OFF
button (3) and the small flame button (2) simultaneously (2 sec) to switch from ºF (and the 12-hour indication)
to the ºC (and the 24-hour indication), and vice versa.
Possible settings
•
By pressing the
SET
button (4) you can switch quickly between
MAN
day temperature
lamp
ventilator
night
temperature
timer
MAN
.
•
MAN
: this setting allows you to turn the flames manually higher or lower with the big-flame button (1) or the small-flame
button (2).
•
Day temperature
(
): this mode allows you to set the desired daytime temperature; the remote control set will function as
a thermostat.
•
The
Lighting
and
fan
are not activated by default. Your installation mechanic can activate these functions, should you want
this. However, this does require you to connect an optional function box (Mertik G6R-BEAV2, art. no. INK.3255).
•
Night temperature
(
): this mode allows you to set the desired night temperature.
•
TIMER
: this mode allows you to preset 2 switch-on and 2 switch-off times per 24 hours. If the night setting is on - - -, the stove
will burn on the pilot flame.
Setting the temperature
•
Select the day temperature or night temperature by briefly pressing
SET
button (4).
•
Now press
SET
button (4) longer until the display starts flashing.
•
Preset the temperature with buttons (1) or (2) (5 ºC is the minimum day temperature).
•
Wait or press
OFF
button (3) to switch back to the thermostat-controlled system.
•
In order to save the batteries you are advised to reset the night-temperature until the display shows the ‘- - -‘ signal.
Setting the timer function
•
Select the timer function by briefly pressing
SET
button (4) a few times.
•
Now press the
SET
button (4) longer until P1 (
) starts flashing.
•
Set the hours with button (1) and the minutes with button (2).
•
Briefly press
SET
button (4) for the next timing.
•
Once all 4 timings have been set, press
OFF
button (3) to end the presetting.
Operation (standard remote control)
Igniting the fire
•
Open the gas turncock that is fixed in the gas pipe leading to the stove.
•
Press “
O I
” switch (5) on the gas control block in the “
I
” position.
•
Turn control button (6) on the gas control block to the
ON
position.
•
Simultaneously press buttons (3) and (1) on the handset. A short acoustic signal
indicates the start, and is followed by short acoustic signals (0.2 sec/signal, 1Hz.)
until the pilot flame and the chief burner are ignited. After the main burner has lit,
the flame height will automatically go to the maximum position.
Possible error messages
•
Long signals (0.8 sec. signal with 0.2 sec. interval) during lighting
: batteries of the receiver are almost empty. (After hearing
this signal, you can switch on the appliance for about another 10 times.)
•
5 seconds continuous signal
: error message. One of the cables may not be connected, or the “
O I
” switch is not in the “
I
”
position.
•
5 short signals (0.2 sec. signal with 0.2 sec. interval)
: ignition of the pilot flame and the main burner has failed. Possible
cause: air in the pilot burner pipe.
Important: If the pilot flame has gone out you must wait at least 5 MINUTES before repeating the above-
mentioned steps.
Setting the height of the flames
•
After igniting the burner, the height of the flames will automatically reach the maximum position.
Summary of Contents for Larix