25
GB
The guarantee includes all defects which can be reduced to flaws in material and construction, in which case you will receive
the new parts free of charge. Labour costs or other expenses are not covered by the guarantee. You can send defect parts
(carriage paid) to WANDERS Metaalproducten B.V., Amtweg 4, 7077 AL in Netterden [The Netherlands].
The guarantee does not include: glass, failure due to improper use; non-compliance with the installation and operating
instructions; installation by a non-certified installer; negligence of the apparatus and converting the hearth to be fired with
another kind of gas.
WANDERS cannot be held responsible for any cracks in stuccoed walls or discolouration of walls, ceilings and/or grates after
burning the fireplace. Discolouration is caused by dust particles burning in the convection cover. To reduce the chance of
cracks in stucco and to minimize discolouration we refer to the advice given for decorative hearths. Your installer can give you
more information.
Any complaints will be dealt with after the sales firm, the installer or the gas company has filed a complaint and sent a copy
of the purchase receipt with purchase date. Any repairs do not entitle you to extend the guarantee term. All consequential
damages or loss are excluded.
Installation instructions
Your gas fireplace may only be installed by a qualified installation mechanic in combination with the concentric channel
system recommended by WANDERS (M&G or Ontop Metaloterm). Only then will the fireplace be approved in accordance
with the European CE directive for appliances burning gaseous fuels. We do not offer a warranty if the gas stove has been
connected and/or installed incompletely or incorrectly. The channel system consists of an inner channel with a diameter
of 100 millimetres and an outside channel with a diameter of 150 millimetres. The flue gases are exhausted outside via the
inner 100-millimetre channel through natural draught, while combustion air is supplied between the 100-millimetre and
150-millimetre channels.
The appliance may only be installed and connected by a certified installer in accordance with the standard gas installation
instructions and the installation requirements mentioned below. Furthermore, the national and local rules and regulations on
placing and using closed gas appliances shall be applicable. Only a certified installer has the authority to change the setting
values (in accordance with the requirements) and to carry out any other adjustments.
Before installing the appliance, the installer must check whether the information on the type tag of the fireplace
corresponds with the gas type and gas pressure to which the appliance is connected. If it does not match, you
are not allowed to connect the gas hearth.
Placing
The gas fireplace can be placed in a crack-free and/or mechanically ventilated home without difficulty. There is no need for
extra ventilation for combustion or for a smoke and fire vent. Waste gases are discharged by natural draught via the inner pipe
into the open. The oxygen needed for burning the fire is supplied from the space between the pipes. This is the reason that no
insulation must be placed between the inner and outer pipe.
The gas heater is not suitable for a built-in setup and should be mounted to a sufficiently sturdy wall or placed
on a sufficiently sturdy floor.
Insulation
Due to the high temperatures of the exterior walls (up to approximately 150 °C or 300 °F) it is prohibited to have or to place
any combustible materials close to the channel system. The entire concentric pipe system should be encased with fireproof
material from the place where it is out of sight up to the outlet in the exterior wall. Ventilate the encased concentric pipe
system by placing a grate near the floor and the ceiling on every floor. Use universal wall clips with a diameter of 150 mm for
anchoring the concentric pipe system.
Summary of Contents for Larix
Page 71: ......