28
GB
Gastype
A (min.-max.)
B (min. - max.)
Reducer
Gastype
A (min. - max)
Reducer
Nat. gas
1,0 - 3,0 m
0,0 - 0,5 m
35 mm
Nat. gas
3,0 - 10,0 m
60 mm
Propane/
Butane
-
Propane/
Butane
80 mm
Nat. gas
1,0 - 3,0 m
1,0 - 3,0 m
-
Nat. gas
1,0 - 3,0 m
50 mm
Propane/
Butane
60 mm
Propane/
Butane
1,0 - 3,0 m
1,0 - 2,0 m
-
all dimensions are exclusive the length of the wall outlet
all dimensions are exclusive the length of the roof outlet
Gastype
B (min. -
max.)
A1 (min. -
max.)
A1 + A2 (min. -
max.)
Reducer
Nat. gas
1,0 - 3,0 m
1,0 - 10,0 m
1,0 - 10,0 m
-
Propane/
Butane
1,0 - 2,0 m
-
(A1 + A2 : B) : 1 Proportion vertical: horizontal (or 45
o
up) is
always at least 2 : 1
all dimensions are exclusive the length of the roof outlet
Placing the pipe system fi rst and then placing the hearth
You can also place the concentric pipe system before placing the appliance. In such case, ensure that you make the connection
with the appliance with an extendable pipe.
Opening (and closing) the door
To operate the wood set and restriction plate, if applicable, the heater must be opened fi rst. To do so, follow these steps: