26
The technical specifi cations from the fans and the control unit are as follows:
Control unit:
Voltage
230V
/
50Hz
Size (L x W x H)
75 x 26 x 20 mm
Fan:
230V ~ 50Hz 120 mA 20W
Connecting the stove
The Square is a heavy insert. Check whether the fl oor on which the stove is placed can carry this weight without
problem. You must follow the directions given in de previous chapter on ‘Preparation” before installing.
Please mind your back and the fl oor during installation!
1. Check the packing. If you detect any visible damage, please notify the supplier.
2. Take the stove from the box.
3. Remove the fl ue collar from the stove by unscrewing the 4 bolts.
4. Place the insert at it’s fi nal position. Make sure that it is positioned right beneath the chimney. If the fans
are installed please make sure the wire does not crack or break during installation.
5. Connect the fl ue collar to the fl ue system with the upper sections fi tting into the lower sections.
6. Place the baffl
e plate into the stove.
7. Your stove is ready for use.
4 x M6